General comment AQUAPROOF REACTIVE (TH) is a solvent-free reactive waterproofing coating.
AQUAPROOF REACTIVE (TH) is applied by paintbrush or roller to form a flexible waterproof membrane, with adhesion to various surfaces. AQUAPROOF REACTIVE can also be applied on damp surfaces and is suitable for both horizontal and vertical applications.
Product types:
AQUAPROOF REACTIVE is the standard product type
AQUAPROOF REACTIVE TH is the thixotropic type
Product packaging: 310 ml / 4 kg / 7.5 kg / 18 kg
Indicative consumption: 1,5 kg/m².
Product composition:
Type of raw materialPercentage (%)Weight per unit (kg)Polymers50 %0.75 kgFillers45 %0.675 kgAdditives5 %0.075 kgAQUAPROOF REACTIVE (TH) has the following certifications:
- ETA (European Technical Approval): 25/0246
- ATG (Agrément Technique/Technische goedkeuring): 3344
The EPD declares an average consumption of the product Aquaproof Reactive TH.
DensityEN ISO 28111.36 kg/literSolidsEN ISO 325197 %Initial setting 1 hourInstant rain resistanceEN 15816PassWater vapour resistanceEN 1931Sd: 1.5 - 2.5 (µ: 751)Elongation resistanceEN ISO 527-3344%Tensile strength – stress at breakEN ISO 527-31.45 MPa ViscosityEN ISO 3219 4.3 +/- 0,5 mPa.sec Waterproofing EN 14891 A.7. Pass Crackbridging EN 14891 par. A.8. > 0.75 mm
Background data was taken from the Ecoinvent 3.9.1 database. The database is regularly checked and thus complies with the requirements of ISO 14040/44 (background data not older than 10 years). The background data meets the requirements of EN 15804. The general rule was followed that specific data from specific production processes or average data derived from specific processes must be given priority when calculating an EPD or Life Cycle Assessment. Data for processes that the manufacturer cannot influence or choose, were backed up with generic data.
The following estimates and assumptions have been made for this EPD:
Energy: only complete energy information for 2024 is available at the time of drafting this EPD, hence data in this EPD is measured data from 2024.
Production waste is quantified based on measured data.
Waste generated on construction sites during application is estimated, as it strongly depends on user practices and site conditions.
Transport of the finished product to construction site is assumed.
The scenarios included are currently in use and are representative for one of the most likely scenario alternatives. According to the criteria of the "UN Environmental Global Guidance on LCA database development" mentioned in EN 15804+A2, the data quality for all three representativeness categories (geographical, technical and time) can be described as good.
The calculations have been performed in accordance with the “polluter pays” and “modularity” principles, as defined in EN 15804+A2. |